Solórzano, A., Rodríguez-Pérez, R., Padilla, M., Graunke, T., Fernandez, L., Marco, S., Fonollosa, J., (2018). Multi-unit calibration rejects inherent device variability of chemical sensor arrays Sensors and Actuators B: Chemical 265, 142-154

Inherent sensor variability limits mass-production applications for metal oxide (MOX) gas sensor arrays because calibration for replicas of a sensor array needs to be performed individually. Recently, calibration transfer strategies have been proposed to alleviate calibration costs of new replicas, but they still require the acquisition of transfer samples. In this work, we present calibration models that can be extended to uncalibrated replicas of sensor arrays without acquiring new samples, i.e., general or global calibration models. The developed methodology consists in including multiple replicas of a sensor array in the calibration process such that sensor variability is rejected by the general model. Our approach was tested using replicas of a MOX sensor array in the classification task of six gases and synthetic air, presented at different background humidity and concentration levels. Results showed that direct transfer of individual calibration models provides poor classification accuracy. However, we also found that general calibration models kept predictive performance when were applied directly to new copies of the sensor array. Moreover, we explored, through feature selection, whether particular combinations of sensors and operating temperatures can provide predictive performances equivalent to the calibration model with the complete array, favoring thereby the existence of more robust calibration models.

Keywords: Gas sensor array, MOX sensor, Robust calibration, Calibration transfer, Machine olfaction


Fonollosa, J., Fernández, L., Gutiérrez-Gálvez, A., Huerta, R., Marco, S., (2016). Calibration transfer and drift counteraction in chemical sensor arrays using Direct Standardization Sensors and Actuators B: Chemical 236, 1044-1053

Inherent variability of chemical sensors makes it necessary to calibrate chemical detection systems individually. This shortcoming has traditionally limited usability of systems based on metal oxide gas sensor arrays and prevented mass-production for some applications. Here, aiming at exploring calibration transfer between chemical sensor arrays, we exposed five twin 8-sensor detection units to different concentration levels of ethanol, ethylene, carbon monoxide, or methane. First, we built calibration models using data acquired with a master unit. Second, to explore the transferability of the calibration models, we used Direct Standardization to map the signals of a slave unit to the space of the master unit in calibration. In particular, we evaluated the transferability of the calibration models to other detection units, and within the same unit measuring days apart. Our results show that signals acquired with one unit can be successfully mapped to the space of a reference unit. Hence, calibration models trained with a master unit can be extended to slave units using a reduced number of transfer samples, diminishing thereby calibration costs. Similarly, signals of a sensing unit can be transformed to match sensor behavior in the past to mitigate drift effects. Therefore, the proposed methodology can reduce calibration costs in mass-production and delay recalibrations due to sensor aging. Acquired dataset is made publicly available.

Keywords: Calibration transfer, Chemical sensors, Direct Standardization, Electronic nose, MOX sensors, Public dataset


Fernandez, L., Guney, S., Gutierrez-Galvez, A., Marco, S., (2016). Calibration transfer in temperature modulated gas sensor arrays Sensors and Actuators B: Chemical 231, 276-284

Abstract Shifts in working temperature are an important issue that prevents the successful transfer of calibration models from one chemical instrument to another. This effect is of special relevance when working with gas sensor arrays modulated in temperature. In this paper, we study the use of multivariate techniques to transfer the calibration model from a temperature modulated gas sensor array to another when a global change of temperature occurs. To do so, we built 12 identical master sensor arrays composed of three different types of commercial Figaro sensors and acquired a dataset of sensor responses to three pure substances (ethanol, acetone and butanone) dosed at 7 concentrations. The master arrays are then shifted in temperature (from −50 to 50 °C, ΔT = 10 °C) and considered as slave arrays. Data correction is performed for an increasing number of transfer samples with 4 different calibration transfer techniques: Direct Standardization, Piece-wise Direct Standardization, Orthogonal Signal Correction and Generalized Least Squares Weighting. In order to evaluate the performance of the calibration transfer, we compare the Root Mean Square Error of Prediction (RMSEP) of master and slave arrays, for each instrument correction. Best results are obtained from Piece-wise Direct standardization, which exhibits the lower RMSEP values after correction for the smaller number of transfer samples.

Keywords: Calibration transfer, Gas sensor array, MOX, Temperature modulation


Fonollosa, J., Neftci, E., Huerta, R., Marco, S., (2015). Evaluation of calibration transfer strategies between Metal Oxide gas sensor arrays Procedia Engineering EUROSENSORS 2015 , Elsevier (Freiburg, Germany) 120, 261-264

Abstract Inherent variability of chemical sensors makes necessary individual calibration of chemical detection systems. This shortcoming has traditionally limited usability of systems based on Metal Oxide (MOX) sensor arrays and prevented mass-production for some applications. Here, aiming at exploring transfer calibration between electronic nose systems, we exposed five identical 8-sensor detection units to controlled gas conditions. Our results show that a calibration model provides more accurate predictions when the tested board is included in the calibration dataset. However, we show that previously built calibration models can be extended to other units using a reduced number of measurements. While baseline correction seems imperative for successful baseline correction, among the different tested strategies, piecewise direct standardization provides more accurate predictions.

Keywords: Electronic nose, Calibration, MOX sensor, Machine Olfaction


Gramse, G., Kasper, M., Fumagalli, L., Gomila, G., Hinterdorfer, P., Kienberger, F., (2014). Calibrated complex impedance and permittivity measurements with scanning microwave microscopy Nanotechnology 25, (14), 145703 (8)

We present a procedure for calibrated complex impedance measurements and dielectric quantification with scanning microwave microscopy. The calibration procedure works in situ directly on the substrate with the specimen of interest and does not require any specific calibration sample. In the workflow tip-sample approach curves are used to extract calibrated complex impedance values and to convert measured S11 reflection signals into sample capacitance and resistance images. The dielectric constant of thin dielectric SiO2 films were determined from the capacitance images and approach curves using appropriate electrical tip-sample models and the εr value extracted at f = 19.81 GHz is in good agreement with the nominal value of εr ∼ 4. The capacitive and resistive material properties of a doped Si semiconductor sample were studied at different doping densities and tip-sample bias voltages. Following a simple serial model the capacitance-voltage spectroscopy curves are clearly related to the semiconductor depletion zone while the resistivity is rising with falling dopant density from 20 Ω to 20 kΩ. The proposed procedure of calibrated complex impedance measurements is simple and fast and the accuracy of the results is not affected by varying stray capacitances. It works for nanoscale samples on either fully dielectric or highly conductive substrates at frequencies between 1 and 20 GHz.

Keywords: Complex impedance, Dielectric constant, Nanotechnology: calibration, Resistivity, Scanning microwave microscopy


Fernandez, L., Marco, S., (2014). Calibration transfer between e-noses Signal Processing and Communications Applications Conference (SIU) Signal Processing and Communications Applications Conference (SIU), 2014 22nd , IEEE (Trabzon, Turkey) , 650-653

Electronic nose is an instrument which is composed of gas sensor array and pattern recognition unit. It is generally used for classifying, identifying or quantifying the odors or volatile organic components for these commonly used devices, calibration transfer is an important issue because of differences in each instrument, sensor drift, changes in environmental conditions or background changes. Calibration transfer is a transfer of model between different instruments which have different conditions. In this study, calibration transfer is applied to the e-noses which have different temperature conditions. Also the results of the direct standardization, piecewise direct standardization and orthogonal signal correction which are different calibration methods were compared. The results of the piecewise direct standardization method are more successful than the other methods for the dataset which is used in this study.

Keywords: Calibration, Conferences, Electronic noses, Ethanol, Instruments, Signal processing, Standardization


Malandrino, Andrea, Noailly, J., Lacroix, Damien, (2013). Regional annulus fibre orientations used as a tool for the calibration of lumbar intervertebral disc finite element models Computer Methods in Biomechanics and Biomedical Engineering , 16, (9), 923-928

The collagen network of the annulus fibrosus largely controls the functional biomechanics of the lumbar intervertebral discs (IVDs). Quantitative anatomical examinations have shown bundle orientation patterns, possibly coming from regional adaptations of the annulus mechanics. This study aimed to show that the regional differences in annulus mechanical behaviour could be reproduced by considering only fibre orientation changes. Using the finite element method, a lumbar annulus was modelled as a poro-hyperelastic material in which fibres were represented by a direction-dependent strain energy density term. Fibre orientations were calibrated to reproduce the annulus tensile behaviours measured for four different regions: posterior outer, anterior outer, posterior inner and anterior inner. The back-calculated fibre angles and regional patterns as well as the global disc behaviour were comparable with anatomical descriptions reported in the literature. It was concluded that annulus fibre variations might be an effective tool to calibrate lumbar spine IVD and segment models.

Keywords: Intervertebral disc, Annulus fibrosus, Model calibration, Fibre orientation


Pomareda, Víctor, Guamán, Ana V., Mohammadnejad, Masoumeh, Calvo, Daniel, Pardo, Antonio, Marco, Santiago, (2012). Multivariate curve resolution of nonlinear ion mobility spectra followed by multivariate nonlinear calibration for quantitative prediction Chemometrics and Intelligent Laboratory Systems , 118, 219-229

In this work, a new methodology to analyze spectra time-series obtained from ion mobility spectrometry (IMS) has been investigated. The proposed method combines the advantages of multivariate curve resolution-alternating least squares (MCR-ALS) for an optimal physical and chemical interpretation of the system (qualitative information) and a multivariate calibration technique such as polynomial partial least squares (poly-PLS) for an improved quantification (quantitative information) of new samples. Ten different concentrations of 2-butanone and ethanol were generated using a volatile generator based on permeation tubes. The different concentrations were measured with IMS. These data present a non-linear behaviour as substance concentration increases. Although MCR-ALS is based on a bilinear decomposition, non-linear behaviour can be modelled adding new components to the model. After spectral pre-processing, MCR-ALS was applied aiming to get information about the ionic species that appear in the drift tube and their evolution with the analyte concentration. By resolving the IMS data matrix, concentration profiles and pure spectra of the different ionic species have been obtained for both analytes. Finally, poly-PLS was used in order to build a calibration model using concentration profiles obtained from MCR-ALS for ethanol and 2-butanone. The results, with more than 99% of explained variance for both substances, show the feasibility of using MCR-ALS to resolve IMS datasets. Furthermore, similar or better prediction accuracy is achieved when concentration profiles from MCR-ALS are used to build a calibration model (using poly-PLS) compared to other standard univariate and multivariate calibration methodologies.

Keywords: Ion Mobility Spectrometry, Multivariate Curve Resolution, Gas phase ion chemistry, Multivariate calibration


Caballero, D., Villanueva, G., Plaza, J. A., Mills, C. A., Samitier, J., Errachid, A., (2010). Sharp high-aspect-ratio AFM tips fabricated by a combination of deep reactive ion etching and focused ion beam techniques Journal of Nanoscience and Nanotechnology , 10, (1), 497-501

The shape and dimensions of an atomic force microscope tip are crucial factors to obtain high resolution images at the nanoscale. When measuring samples with narrow trenches, inclined sidewalls near 90 or nanoscaled structures, standard silicon atomic force microscopy (AFM) tips do not provide satisfactory results. We have combined deep reactive ion etching (DRIE) and focused ion beam (FIB) lithography techniques in order to produce probes with sharp rocket-shaped silicon AFM tips for high resolution imaging. The cantilevers were shaped and the bulk micromachining was performed using the same DRIE equipment. To improve the tip aspect ratio we used FIB nanolithography technique. The tips were tested on narrow silicon trenches and over biological samples showing a better resolution when compared with standard AFM tips, which enables nanocharacterization and nanometrology of high-aspect-ratio structures and nanoscaled biological elements to be completed, and provides an alternative to commercial high aspect ratio AFM tips.

Keywords: Atomic-Force Microscope, Carbon nanotube tips, Probes, Roughness, Cells, Microfabrication, Calibration, Surfaces


Casamitjana, M., Pérez, M. C., Aranda, J., Montseny, E., Martin, E. X., (2010). Reliable 3D reconstruction extending pixel-level certainty measures IEEE International Conference on Fuzzy 2010 IEEE World Congress on Computational Intelligence , IEEE (Barcelona, Spain) , 1-7

A new method for obtaining a three-dimensional volumetric reconstruction from a set of views improving the classical Shape from Silhouette method (SFS) is presented. SFS approaches can be easily accelerated through hardware and software techniques but they are very sensible to errors arising during calibration and segmentation processes so they present difficulties when dealing with real images. This paper proposes a new algorithm which uses the information about pixel segmentation uncertainty contained in each view in order to get a reliable 3D reconstruction of the scene. Aggregation of the projected uncertainties permits to classify scene's voxels by means of a decision rule but also makes it possible to create a three-dimensional confidence map of the scene. As a consequence, the regions where more information is needed can be foreseen. Sample reconstructions from real image sets are presented and evaluated.

Keywords: Calibration, Image classification, Image reconstruction, Image segmentation, 3D reconstruction, Calibration process, Decision rule, Hardware technique, Pixel segmentation, Pixel-level certainty measures, Scene voxel classification, Segmentation process, Shape from silhouette method, Software technique, Three-dimensional confidence map, Three-dimensional volumetric reconstruction


Udina, S., Pardo, A., Marco, S., Santander, J., Fonseca, L., (2008). Thermoelectric MEMS sensors for natural gas analysis Electronic Proceedings of the Seventh IEEE Sensors Conference 2008 Sensors, 2008 IEEE (ed. Frech, P., Siciliano, P.), IEEE (Lecce, Italy) , 1364-1367

T Multivariate data analysis techniques have been used for the first time in thermoelectric MEMS sensors in order to determine the composition of natural gas mixtures. Experimental measurements with different thermoelectric devices have been performed, the gathered data have been used to calibrate the sensor responses to four main components of natural gas: CH4, C2H6, N2 and CO2. Presence of the three first components was predicted with good accuracy while CO2 prediction was poor. Presented results indicate that thremoelectric sensors operated at different heater temperatures open the possibility of low-cost natural gas analysis.

Keywords: Natural gas, Multivariate calibration, Thermal conductivity, Thermal sensor