Rodriguez, J., Schulz, S., Voss, A., Giraldo, B. F., (2019). Cardiovascular coupling-based classification of ischemic and dilated cardiomyopathy patients Engineering in Medicine and Biology Society (EMBC) 41st Annual International Conference of the IEEE , IEEE (Berlín, Germany) , 2007-2010

Cardiovascular diseases are one of the most common causes of death in elderly patients. The etiology of cardiomyopathies is difficult to discern clinically. The objective of this study was to classify cardiomyopathy patients using coupling analysis, through their cardiovascular behavior and the baroreflex response. A total of thirty-eight cardiomyopathy patients (CMP) classified as ischemic (ICM, 25 patients) and dilated (DCM, 13 patients) were analyzed. Thirty elderly control subjects (CON) were used as reference. Their electrocardiographic (ECG) and blood pressure (BP) signals were studied. To characterize the cardiovascular activity, the following temporal series were extracted: beat-to-beat intervals (from the ECG signal), and end- systolic and diastolic blood pressure amplitudes (from the BP signal). Non-linear characterization techniques like high resolution joint symbolic dynamics, segmented Poincaré plot analysis, normalized shorttime partial directed coherence, and dual sequence method were used to characterize these times series. The best indices were used to build support vector machine models for classification. The optimal model for ICM versus DCM patients achieved 84.2% accuracy, 76.9% sensitivity, and 88% specificity. When CMP patients and CON subjects were compared, the best model achieved 95.5% accuracy, 97.3% sensitivity, and 93.3% specificity. These results suggest a disfunction in the baroreflex mechanism in cardiomyopathies patients.

Keywords: Couplings, Time series analysis, Support vector machines, Electrocardiography, Baroreflex, Coherence, Sensitivity


Aragonès, A. C., Aravena, D., Cerdá, J. I., Acís-Castillo, Z., Li, H., Real, J. A., Sanz, F., Hihath, J., Ruiz, E., Díez-Pérez, I., (2016). Large conductance switching in a single-molecule device through room temperature spin-dependent transport Nano Letters 16, (1), 218-226

Controlling the spin of electrons in nanoscale electronic devices is one of the most promising topics aiming at developing devices with rapid and high density information storage capabilities. The interface magnetism or spinterface resulting from the interaction between a magnetic molecule and a metal surface, or vice versa, has become a key ingredient in creating nanoscale molecular devices with novel functionalities. Here, we present a single-molecule wire that displays large (>10000%) conductance switching by controlling the spin-dependent transport under ambient conditions (room temperature in a liquid cell). The molecular wire is built by trapping individual spin crossover FeII complexes between one Au electrode and one ferromagnetic Ni electrode in an organic liquid medium. Large changes in the single-molecule conductance (>100-fold) are measured when the electrons flow from the Au electrode to either an α-up or a β-down spin-polarized Ni electrode. Our calculations show that the current flowing through such an interface appears to be strongly spin-polarized, thus resulting in the observed switching of the single-molecule wire conductance. The observation of such a high spin-dependent conductance switching in a single-molecule wire opens up a new door for the design and control of spin-polarized transport in nanoscale molecular devices at room temperature.

Keywords: Density functional calculations, Magnetoresistance, Single-molecule junctions, Spin orbit coupling, Spin-crossover complexes, Spinterface, STM break-junction